For several years, CHANGXIN have specialized in trading high-quality components in the field of industrial automation.
Focusing on PLC components, DCS and CNC technology, and drivetechnology
GE Control System IS215WEMAH1A Ethernet Multi Channel Adaptation Board
| Brand: GE Mark VIe |
| Item NO: IS215WEMAH1A |
| Effect: Ethernet Multi Channel Adaptation Board |
| Condition: In stock, brand new/Used |
| Warranty: 365 days |
| Payment:T/T 50% deposit, 50% balance |
| www.szcxdcs.com |
+86 15359298293
GE Control System IS215WEMAH1A Ethernet Multi Channel Adaptation Board
IS215WEMAH1A is a WEMA broadband Ethernet multi-channel adapter board for GE Vernova (formerly GE) Mark VIe control system, which also integrates BPPS auxiliary power monitoring function. It belongs to the network communication interface board and is commonly used in wind turbine control cabinet A.
IS215WEMAH1A Ethernet Multi Channel Adaptation Board serves as the Mark VIe main control and upper layer factory network HMI、 The Ethernet adapter unit between the engineer station and DCS system is used to achieve control network data forwarding, multiplexing of multiple Ethernet signals, and network isolation; IS215WEMAH1A is equipped with an onboard power monitoring circuit, which monitors the power supply status of the cabinet in real time, uploads network link and power failure alarms, and ensures stable transmission of real-time data, event recording, and fault recording between the main control and upper system. It is the core communication board for network expansion of wind power and gas turbine Mark VIe systems.

Main product range
- Control system (DCS/PLC/CNC): panel controller, HMI and human-machine interface, industrial PC, CPU processor module, communication module, analog/digital I/O module
- Drive and motion control: frequency converter, servo drive, servo motor, power module
- Robot spare parts: key spare parts such as robot control board, axis computer, servo unit, I/O module, etc
- State monitoring and safety system: vibration monitoring system, safety instrumented system (SIS), redundant controller
Application Industry
The products are widely used in various industrial fields such as metallurgy, oil and gas, petrochemicals, electricity, power transmission and distribution, water conservancy, water treatment and environmental protection, coal mining, aluminum industry, glass manufacturing, paper and printing, textile printing and dyeing, machinery manufacturing, electronics manufacturing, automobile manufacturing, plastic machinery, boiler heating, energy, etc.
GE Control System IS215WEMAH1A Ethernet Multi Channel Adaptation Board
Product Features
- Dual Ethernet port design, supporting automatic negotiation of 10/100M, achieving isolated forwarding between control network and factory level monitoring network, and improving network security.
- Integrate BPPS power monitoring circuit, synchronously monitor the power supply status of the cabinet, and provide early warning for power abnormalities.
- Broadband Ethernet multiplexing adaptation can achieve multi-channel network data aggregation and forwarding, reducing switch configuration.
- Electrical isolation design to isolate upper level factory network interference and protect Mark VIe from real-time control of the internal network.
- Supports TCP/UDP, Modbus TCP, and 104 protocols for easy integration with third-party DCS, SCADA, and upper HMI.
- The board is coated with three anti coatings to prevent moisture and dust, and is suitable for harsh working conditions such as wind turbine tower control cabinets and gas turbine rooms.
- Support hot swapping, online replacement of spare parts, without affecting the operation of the unit’s control and protection circuits.
- Equipped with link, activity, and fault indicator lights, it can quickly locate power outages and power failures during debugging and inspection.
- Equipped with network fault diagnosis, real-time reporting system for packet loss, link interruption, and voltage abnormalities.
- Specially designed for Mark VIe wind power control cabinet A, it is a standard network adaptation board for the wind turbine main control system.


Main brand
| No. | Brand | Country/Region | Main Product Lines | Typical Series/Models |
| 1 | ABB | Switzerland | PLC/DCS Controllers, I/O Modules, Robot Spare Parts, Drive Systems | AC800PEC,AC800M, AC800F, AC31, 800xA, Bailey INFI 90, DSQC Robot Modules, Advant OCS, H&B Freelance |
| 2 | Bently Nevada | USA | Condition Monitoring Systems, Vibration Sensors, Proximitors | 3500 Monitoring System, 3300 Monitoring System, Eddy Current Probes, Proximitors |
| 3 | TRICONEX | USA | Safety Instrumented Systems (SIS), TMR Redundant Controllers | Tricon System Modules, Communication Modules, I/O Modules |
| 4 | Woodward | USA | Steam/Gas Turbine Control, Speed Governing Systems, Actuators | 505 Governor, ProTech, MicroNet, NetCon Series |
| 5 | FOXBORO | USA | DCS Systems, I/A Series Control Modules | I/A Series, FBM Modules, Controllers |
| 6 | WESTINGHOUSE | USA | DCS Systems, Ovation Controllers, Modules | Ovation System, WDPF Series |
| 7 | Motorola | USA | Industrial Communication Modules, Embedded Control Modules | MVME Series, VME Bus Modules |
| 8 | GE | USA | PLC, Excitation System Modules, CPU/Communication/Analog Modules | IS200/DS200 Excitation Cards, IC693/IC695/IC697/IC698/IC200/IC660/IC670 Series |
| 9 | YOKOGAWA | Japan | DCS Systems, CPU Modules, I/O Cards | CENTUM CS3000, CS1000, VP Series |
| 10 | HIMA | Germany | Safety Control Systems, SIL Safety Modules | H41q/H51q, HIMax, HIMatrix Series |
| 11 | EMERSON | USA | DCS Systems, Redundant Controllers, Safety Systems | Ovation, DeltaV Dual-Channel Redundant Safety Systems |
| 12 | Honeywell | USA | DCS Systems, Process Control Modules | Experion PKS/LS/HS, Plant Scape, TDC2000, TDC3000, TPS, Alcont |
| 13 | ICS TRIPLEX | UK | Trusted Safety Control Systems, TMR Modules | Trusted System, T8000 Series |
| 14 | Kollmorgen | USA | Servo Drives, Servo Motors, Motion Control | S700, S300, AKD Series Drives, Servo Motors |
| 15 | PROSOFT | USA | Industrial Communication Modules, Protocol Gateways | MVI69, MVI56, MVI94, MVI71, MVI46, PS69, 3150 Series |
| 16 | Alstom | France | Power Control, Protection Relays, Control Systems | GEC ALSTHOM, Protection and Control Modules |
| 17 | EATON | USA | Electrical Control, PLC, Power Supplies, Circuit Breakers | XC/XN Series PLC, Moeller Series, Power Supply Modules |
| 18 | Allen-Bradley (Rockwell) | USA | PLC Controllers, I/O Modules, Communication Modules | ControlLogix 1756, CompactLogix 1769, SLC 500 1747/1746, PLC-5 1771/1785 |
| 19 | Schneider | France | PLC, Modicon Series, CPU/Communication Modules | Quantum 140, Modicon M340, Modicon Premium |
————————Shenzhen Changxin Automation Equipment Co Ltd -————————
Products that have been released are welcome for consultation. Due to the wide variety of models, we were unable to upload physical images one by one!
![]()

Parameter Specifications
| Item | Specification |
|---|---|
| Part Number | IS215WEMAH1A |
| Series | Mark VIe Speedtronic Control System |
| Module Type | WEMA Wide Ethernet Multiplexed Adapter Board |
| Application Cabinet | Cabinet A |
| Ethernet Port | Dual 10/100 Base-TX, RJ45 |
| Network Communication Rate | 10Mbps / 100Mbps auto-negotiation |
| Network Protocol | TCP/IP, UDP, IEC 60870-5-104, Modbus TCP |
| Power Supply Monitoring | BPPS power supply monitoring circuit integrated |
| Backplane Power Supply | DC28V (18V ~ 32V DC) |
| Power Consumption | 10W ~ 16W |
| Galvanic Isolation | Network isolation between control network and plant network |
| Communication Delay | ≤ 1ms |
| Operating Temperature | -30℃ ~ +65℃ |
| Storage Temperature | -40℃ ~ +85℃ |
| Relative Humidity | 5% ~ 95%, non-condensing |
| Mounting Method | Standard Mark VIe rack slot installation |
| Hot Swap | Support hot swap |
| Conformal Coating | Anti-corrosion conformal coating |
| Diagnostic Indicator | LINK, ACT, FAULT, POWER LED |
| EMC Standard | IEC 61000 series |
| Certification | CE |
| Fault Diagnosis | Network link loss, packet error, power undervoltage, overvoltage alarm |
| Data Function | Event log, disturbance recorder data upload |
| Dimension | 220mm × 120mm × 25mm |
| Net Weight | Approx. 0.34 kg |
| Supported System | Mark VIe Turbine / Wind Turbine Control |