For several years, CHANGXIN have specialized in trading high-quality components in the field of industrial automation.
Focusing on PLC components, DCS and CNC technology, and drivetechnology
BENDER IRDH275B-427 ISOMETER series insulation monitoring device
| Brand: BENDER |
| Item NO: IRDH275B-427 |
| Effect: ISOMETER series insulation monitoring device |
| Condition: In stock, brand new/Used |
| Warranty: 365 days |
| Payment:T/T 50% deposit, 50% balance |
| www.szcxdcs.com |
+86 15359298293
BENDER IRDH275B-427 ISOMETER series insulation monitoring device
IRDH275B-427 is BENDER ISOMETER ® The series insulation monitoring device adopts the AMPPlus measurement principle and is compatible with ungrounded AC/DC hybrid IT systems, with a maximum AC793V and DC650V. Dual threshold alarm, equipped with BMS protocol RS485 communication and clock fault memory, can automatically adapt to system distributed capacitance, used for real-time monitoring of insulation resistance, early warning of grounding faults, and ensuring power supply safety.

Product Introduction and Function
Introduction: IRDH275B-427 is a German BENDER Bendel Insulation Monitor (IMD), which is a discontinued spare part designed specifically for ungrounded IT power grids. It supports AC/DC hybrid systems with rectifier and inverter loads. The B version has a built-in real-time clock, isolated 4-20mA analog output, and BMS bus interface, which is different from the regular IRDH275 base model.
Function: Continuously monitor the insulation resistance of the IT system to ground; When the insulation degradation reaches the first and second level thresholds, two relay alarms are triggered respectively; Record the time of malfunction; Upload insulation data to the upper computer; Equipped with a self checking circuit, it monitors instrument malfunctions to avoid the risk of short circuit or fire after a single point grounding.
Parameter Specifications
| Item | Specification |
|---|---|
| Part Number | IRDH275B-427 |
| Brand | BENDER |
| Measuring Principle | AMP®Plus adaptive measuring pulse |
| Rated System Voltage | 3AC/AC 0…793 V, DC 0…650 V |
| Response Value Range | 1 kΩ … 10 MΩ, two independent adjustable thresholds |
| Supply Voltage | 19.2 ~ 72 VDC |
| Power Consumption | 8 VA |
| Frequency Range | DC, 0.2 ~ 460 Hz |
| Relay Output | 2 potential-free changeover contacts, 250 VAC / 5 A |
| Communication Interface | RS485, BMS protocol |
| Analog Output | Galvanically isolated 0/4…20 mA |
| Display | Backlit two-line LCD |
| Real-time Clock & Fault Memory | Yes (B version only) |
| Self-test Function | Manual / automatic self-test |
| External Test / Reset | Support external test & reset terminal |
| Operating Temperature | -25 °C ~ +70 °C |
| Storage Temperature | -40 °C ~ +85 °C |
| Relative Humidity | 5% ~ 95 %, non-condensing |
| Protection Class | IP30 (front IP40 with cover) |
| Mounting | 35 mm DIN rail |
| Dimension (W×H×D) | 144 mm × 148 mm × 68 mm |
| Weight | 0.52 kg |
| Approval | CE, GL, DNV |
| Country of Origin | Germany |
Product features
- AMPPlus patented measurement algorithm ensures stable measurement in high distribution capacitor cables and harmonic scenarios of frequency converters, making it less prone to false alarms
- Two independent adjustable alarm thresholds, graded warning (pre alarm+main alarm)
- Version B comes with a real-time clock and timestamp storage for faults, making it easy to trace the process of insulation degradation
- Isolate 4-20mA analog output+BMS RS485 bus, connect to PLC, SCADA, and upper monitoring system
- Support local button test reset, and can also be connected to remote test reset terminals externally
- Built in self-monitoring, automatic alarm for instrument disconnection and abnormal power supply
- DIN rail installation, backlit LCD real-time display of insulation resistance value and system leakage capacitance
- Can be matched with couplers to expand voltage levels and adapt to high-voltage IT systems
Usage scenario
- Ship, offshore platform, rail transit traction ungrounded IT power supply system
- Industrial IT power grid with variable frequency drive, DC speed regulation, and rectified load
- Non grounded power supply circuit in mining and oil and gas explosion-proof areas
- Uninterruptible Power Supply (UPS), Energy Storage DC IT System
- Monitoring of Safety Power Supply for Key Equipment in Water Treatment, Metallurgy, and Ports
BENDER IRDH275B-427 ISOMETER series insulation monitoring device


Replacement precautions
- IRDH275B-427 cannot be directly interchanged with IR427 and isoMED series, as the measurement principles, terminal definitions, and alarm logic are different
- Confirm that the system voltage is an AC/DC hybrid IT system before replacement; Different models for pure AC, pure DC, and medical IT selection
- For working conditions with long system cables and large distributed capacitance, it is necessary to verify whether AGH coupling devices are required
- The two relay contacts are conversion contacts, distinguishing between normally open/normally closed. When wiring, check the original alarm circuit logic
- After replacement, it is necessary to perform a manual TEST self-test to confirm that the alarm, communication, and analog output are normal
When multiple Bendel insulation monitoring instruments are connected in parallel in the same cabinet, the internal isolation and disconnection function needs to be enabled to prevent mutual interference
Common FAQ
Q1: Why do insulation values jump and cause frequent false alarms?
A: Mostly causing large leakage capacitance for frequency converters and long cables; The AMPPlus model is adaptive, but if the capacitor exceeds the specifications, it still needs to be paired with a coupler or checked for grounding hazards.
Q2: Can MMS and ISODATA protocols directly communicate with each other?
A: I can’t. IRDH275B is BMS, the old IRDH275 is ISODATA, and the upper computer driver program needs to be synchronously modified.
Q3: Can it be used in TN grounding system?
A: No, this product is only suitable for * * IT ungrounded systems * *, TN systems cannot be monitored normally.
Q4: Is 4-20mA analog isolated?
A: Yes, with instrument power supply and RS485 electrical isolation to reduce interference.
Q5: Is the alarm relay a passive contact?
A: Both channels are passive conversion contacts and can be connected to AC250V 5A circuits.
Main brand
| No. | Brand | Country/Region | Main Product Lines | Typical Series/Models |
| 1 | ABB | Switzerland | PLC/DCS Controllers, I/O Modules, Robot Spare Parts, Drive Systems | AC800PEC,AC800M, AC800F, AC31, 800xA, Bailey INFI 90, DSQC Robot Modules, Advant OCS, H&B Freelance |
| 2 | Bently Nevada | USA | Condition Monitoring Systems, Vibration Sensors, Proximitors | 3500 Monitoring System, 3300 Monitoring System, Eddy Current Probes, Proximitors |
| 3 | TRICONEX | USA | Safety Instrumented Systems (SIS), TMR Redundant Controllers | Tricon System Modules, Communication Modules, I/O Modules |
| 4 | Woodward | USA | Steam/Gas Turbine Control, Speed Governing Systems, Actuators | 505 Governor, ProTech, MicroNet, NetCon Series |
| 5 | FOXBORO | USA | DCS Systems, I/A Series Control Modules | I/A Series, FBM Modules, Controllers |
| 6 | WESTINGHOUSE | USA | DCS Systems, Ovation Controllers, Modules | Ovation System, WDPF Series |
| 7 | Motorola | USA | Industrial Communication Modules, Embedded Control Modules | MVME Series, VME Bus Modules |
| 8 | GE | USA | PLC, Excitation System Modules, CPU/Communication/Analog Modules | IS200/DS200 Excitation Cards, IC693/IC695/IC697/IC698/IC200/IC660/IC670 Series |
| 9 | YOKOGAWA | Japan | DCS Systems, CPU Modules, I/O Cards | CENTUM CS3000, CS1000, VP Series |
| 10 | HIMA | Germany | Safety Control Systems, SIL Safety Modules | H41q/H51q, HIMax, HIMatrix Series |
| 11 | EMERSON | USA | DCS Systems, Redundant Controllers, Safety Systems | Ovation, DeltaV Dual-Channel Redundant Safety Systems |
| 12 | Honeywell | USA | DCS Systems, Process Control Modules | Experion PKS/LS/HS, Plant Scape, TDC2000, TDC3000, TPS, Alcont |
| 13 | ICS TRIPLEX | UK | Trusted Safety Control Systems, TMR Modules | Trusted System, T8000 Series |
| 14 | Kollmorgen | USA | Servo Drives, Servo Motors, Motion Control | S700, S300, AKD Series Drives, Servo Motors |
| 15 | PROSOFT | USA | Industrial Communication Modules, Protocol Gateways | MVI69, MVI56, MVI94, MVI71, MVI46, PS69, 3150 Series |
| 16 | Alstom | France | Power Control, Protection Relays, Control Systems | GEC ALSTHOM, Protection and Control Modules |
| 17 | EATON | USA | Electrical Control, PLC, Power Supplies, Circuit Breakers | XC/XN Series PLC, Moeller Series, Power Supply Modules |
| 18 | Allen-Bradley (Rockwell) | USA | PLC Controllers, I/O Modules, Communication Modules | ControlLogix 1756, CompactLogix 1769, SLC 500 1747/1746, PLC-5 1771/1785 |
| 19 | Schneider | France | PLC, Modicon Series, CPU/Communication Modules | Quantum 140, Modicon M340, Modicon Premium |
————————Shenzhen Changxin Automation Equipment Co Ltd -————————
Products that have been released are welcome for consultation. Due to the wide variety of models, we were unable to upload physical images one by one!
![]()

###Related supporting spare parts
-AGH675S-7: High Voltage Coupling Device (Extended Monitoring Voltage)
-PRC1470: BMS bus remote display control unit
-CP305: Remote Alarm Indicator
-EDS series: Insulation fault locator (matched with fault finding branch)
-IRDH275BM-7: Upgraded replacement model within the same series
-IRDH575: New generation full range replacement models