Product Categories
CHANGXIN Module Spare Parts

For several years, CHANGXIN have specialized in trading high-quality components in the field of industrial automation.

Focusing on PLC components, DCS and CNC technology, and drivetechnology

Get Instant Quote
Contact Form Demo (#3)

Eaton MTL8000 Series 8922-RB-IS Railbus Bus Isolation Module

Brand: Eaton MTL
Item NO: 8922‑RB‑IS
Effect: Perform current isolation on the Railbus bus
Condition: In stock, brand new/Used
Warranty: 365 days
Payment:T/T 50% deposit, 50% balance
www.szcxdcs.com
Telephone

+86 15359298293

Product Description

Eaton MTL8000 Series 8922-RB-IS Railbus Bus Isolation Module

8922-RB-IS is an Eaton (MTL) MTL8000 series Railbus bus isolation module used for PAC8000 control system backplane bus, achieving electrical isolation between safety zone bus and intrinsic safety (IS) fieldbus. 8922-RB-IS is used for system architecture with intrinsic safety I/O modules, isolating hazardous fault voltages, protecting intrinsic safety side field wiring and I/O cards, and is widely used in explosion-proof hazardous conditions such as chemical and petrochemical industries. It is used as a system supporting spare part.

8922 RB IS 2

 

Eaton MTL8000 Series 8922-RB-IS Railbus Bus Isolation Module

Product function
1. Bus electrical isolation: Perform current isolation on the Railbus bus to block the intrusion of fault voltage from the safe zone side into the intrinsic safety circuit, avoiding the failure of the explosion-proof performance of the intrinsic safety field circuit.
2. Bus segmentation isolation: Divide the backplane bus into two segments: the safety zone (2/2) and the intrinsic safety zone (2/1). The intrinsic safety I/O module must be arranged on the isolated bus segment.
3. Transparent signal forwarding: Isolate and fully forward bus data communication to ensure normal data exchange between the controller and the intrinsic safety side I/O module, without interrupting measurement point acquisition and output control.
4. Intrinsic safety circuit protection: protects intrinsic safety I/O modules and on-site explosion-proof instruments, prevents surge and overvoltage damage to on-site intrinsic safety equipment, and meets safety regulations for explosion-proof areas.
5. System architecture matching: All PAC8000 systems equipped with intrinsic safety I/O modules must be equipped with this isolation module for project construction and replacement of faulty spare parts.

Parameter Specifications

Parameter Name Parameter Value
Product Model 8922‑RB‑IS
Manufacturer Eaton MTL
Product Type Railbus Isolator
Applicable System PAC8000 / MTL8000 Series
Bus Segment Safe‑area 2/2 side, IS 2/1 side
Safe Area Railbus Current 50 mA Max @12 V DC
IS Railbus Current 60 mA Max @12 V DC
Max Power Dissipation 1.2 W
Isolation Voltage 2500 V RMS
Node Address Range 1‑32 / 1‑64 configurable
Installation Mode DIN rail mount on carrier base
Mechanical Dimension 110 × 160 × 42 mm
Net Weight 0.345 kg
Operating Temperature ‑25℃ ~ +70℃
Protection Class IP20
Certification ATEX, IECEx, Class I Div2, Zone2 IIC T4
Application Chemical, Petrochemical hazardous area DCS system, spare parts replacement

8922 RB IS 3 8922 RB IS

Product features
1. Modular DIN rail installation, directly installed on the system carrier base, arranged before the first intrinsically safe I/O carrier.
2. Fully electrically isolated design, isolating the safety zone from the intrinsic safety zone bus, suppressing common mode interference and grounding loop issues.
3. Transparent transmission of bus signals, without changing the bus protocol or adding additional communication delay.
4. Equipped with explosion-proof Zone2/Class I Div2 certification, the module body can be installed in hazardous area cabinets.
5. Using dedicated male and female backplane connectors, directly connected in series to the Railbus bus link without the need for additional wiring.
6. The whole machine is designed with low power consumption, suitable for long-term continuous operation inside the control cabinet, and has no fan for passive heat dissipation.
7. As a necessary infrastructure component of the system, it supports address range configuration and adapts to different numbers of I/O nodes.

GE Mark VIe Series IS220PCNOH1B CANopen Communication I/O Module

T8461C | ICS TRIPLEX Trusted TMR Digital Output Module

GDB021BE01 HIEE300766R0001 Multi-channel Current Acquisition Module

ABB 3BHB030310R0001 5SHY4045L0006 3BHE039203R0101 GVC736CE10 IGCT series power module

PM866A 3BSE076359R1 ABB 800xA System Core Processor Unit (CPU)

PM511V16 3BSE011181R1 ABB Digital signal processing control board

PM891 | 3BSE053240R1 | ABB Central Processing Unit (CPU) Module

3BHE014070R0101 | PPC905AE101 | ABB PLC logic controller board

ABB CI860K01 3BSE032444R1 CI860K01 Implement fieldbus interface function

WOODWARD 9907-1183 505E Series Steam Turbine Digital Speed Control Controller

Woodward GS16 Series 9908-1501 Electric Gas Control Valve

EATON XV 440 10TVB 1 20 1

Share This Page
Related Products
Scroll to Top

Get A Free Quote Now!

Contact Form Demo (#3)