Product Categories
CHANGXIN Module Spare Parts

For several years, CHANGXIN have specialized in trading high-quality components in the field of industrial automation.

Focusing on PLC components, DCS and CNC technology, and drivetechnology

Get Instant Quote
Contact Form Demo (#3)

HIMA HIMax X-CPU 31 Secure CPU Processor Module

Brand: HIMA HIMax
Item NO: HIMax X-CPU 31
Effect: Implement the security control procedures written by the users
Condition: In stock, brand new/Used
Warranty: 365 days
Payment:T/T 50% deposit, 50% balance
www.szcxdcs.com
Telephone

+86 15359298293

Product Description

HIMA HIMax X-CPU 31 Secure CPU Processor Module

X-CPU 31 is an integrated safety CPU processor module specifically developed for small and medium-sized safety applications under the German HIMA HIMax platform. Integrating the CPU core and system bus functions, without the need to separately configure the X-SB01 bus module, it saves rack slot resources and reduces the overall system hardware cost. HIMax X-CPU 31 adopts a two-out-of-two lockstep fault-tolerant architecture, achieving SIL3 safety certification. It is designed for small and medium-sized safety interlock scenarios in process industries, compatible with the entire HIMax hardware ecosystem, supports online program modification and hot-swappable hardware replacement, and the system does not require downtime to ensure continuous operation of the device.

HIMatrix F35 02 副本

Main function
  1. Safety logic operation: Execute user written safety control programs, complete safety interlock logic judgment, and achieve safety functions such as emergency stop, fire and gas protection, and equipment interlock protection.
  2. I/O management scheduling: Unify the management of all safety I/O modules in the local and remote expansion racks, collect on-site signals, output safety action instructions, and support up to 512 points of safety I/O signal processing.
  3. System bus control: Built in system bus function, completes data exchange between modules in the rack, supports dual bus redundancy, and ensures reliable and stable communication between modules.
  4. External communication and interaction: communicate with the upper computer HMI, SCADA, and third-party PLC through Ethernet and RS485 interfaces; Support secure protocol transmission of secure data, enabling event recording, status uploading, and parameter interaction.
  5. Fault diagnosis and event recording: Real time diagnosis of hardware, bus, and I/O faults, saving SOE event timing records, and driving output to enter preset safe states when faults occur, facilitating fault investigation and traceability.
  6. Online maintenance: supports non-stop program download, module hot replacement, online verification testing, and completes maintenance work during device operation to reduce downtime losses.

Applicable scenarios: ESD emergency shutdown system, F&G fire and gas system, boiler BMS combustion management, compressor/turbine unit protection, small and medium-sized device interlocking, pipeline protection system, etc.

HIMA HIMax X-CPU 31 Secure CPU Processor Module

Specification X‑CPU 31
Manufacturer HIMA Paul Hildebrandt GmbH
Module Type Safety Processor Module
Safety Level SIL3(IEC61508), PL e(ISO13849‑1), Cat.4(EN954‑1)
Processor Dual‑core ARM Cortex‑R52, Lock‑step 2oo2 architecture
Flash Memory 16 MB
RAM 8 MB
Max. Safety I/O Points 512 points
Scan Time ≤10 ms
Communication Interface 2 × RJ45 Ethernet, 1 × RS‑485
Supported Protocol SafeEthernet, PROFIsafe, OPC UA, Modbus RTU
SOE Event Storage 5000 events, 1 ms resolution
Diagnosis Log 2500 entries
Power Supply 24 VDC ±10 %, Redundant power input supported
Operating Temperature -40 ℃ ~ +70 ℃
Dimension(W × H × D) 150 mm × 110 mm × 45 mm
Installation Rack‑mount, HIMax backplane

F3237 副本 F8650X. 2 副本

Product features
  • Integrated design: CPU and system bus are integrated into a single module, reducing hardware quantity, freeing up rack I/O slots, simplifying system architecture, and lowering procurement and installation costs.
  • High security fault-tolerant architecture: Dual core lock-in 2oo2 security architecture, meeting IEC61508 SIL3 and ISO13849-1 PL e security levels, with common cause failure protection capability, and hardware failure can achieve safe failure.
  • Online non-stop maintenance: program online download, module hot swappable replacement, online functional testing, maintenance during system operation without interrupting security protection functions; Replacing the CPU module supports automatic recognition configuration without the need to reinstall the project.
  • Powerful diagnosis and SOE events: The module stores a large number of diagnostic logs locally, with a SOE event resolution of 1ms and the ability to record 5000 events, facilitating accident tracing and analysis.
  • Multi tasking program processing: Supports up to 32 user tasks to run in parallel, suitable for complex interlocking logic requirements of small and medium-sized devices.
  • Flexible scalability: supports remote rack and star topology distributed deployment; Compatible with the entire HIMax series I/O and communication modules, capable of expanding system scale in the future
  • Rich communication protocols: Ethernet supports SafeEthernet, PROFIsafe, OPC UA; RS-485 supports Modbus RTU, making it easy to interface with third-party devices.
  • Wide temperature industrial hardware: Suitable for harsh temperature environments in industrial sites, supports redundant 24VDC power input, and improves power supply reliability.

ABB GE EMERSON HIMA