Item NO: C7012E1112/U
Effect: Real time monitoring of flames from gas, fuel, and coal powder burners
Condition: In stock, brand new/Used
Warranty: 365 days
Payment:T/T 50% deposit, 50% balance
www.szcxdcs.com
Telephone

+86 15359298293

Product Description

HONEYWELL C7012E1112/U Self Testing UV Flame Detector

C7012E1112/U is a ultraviolet (UV) flame probe produced by Honeywell. It detects the UV radiation generated by fuel combustion to determine the true state of flames in the furnace, and is a core component of combustion safety protection. C7012E1112/U must be used in conjunction with R7247C/R7847C flame amplifiers for industrial burner flame monitoring.

main function:

  1. Real time monitoring of flames from gas, fuel, and coal powder burners; If there is a valid flame signal output from the fire, a shutdown signal will be sent to the combustion safety controller to trigger the safety interlock to cut off the fuel and prevent furnace explosion accidents.
  2. Built in dynamic self checking shutter mechanism continuously verifies whether the probe sensor is normal, avoiding the dangerous failure mode of “no fire false alarm with fire” caused by probe damage, and meeting the safety regulations for continuous operation of combustion equipment.
  3. Convert the flame ultraviolet signal into an electrical signal and transmit it to the supporting flame amplifier and combustion management system to participate in ignition and extinguishing protection logic.
  4. Support parallel connection of two probes to improve the reliability of low load flame detection and reduce false shutdown situations

C7012E1112U

Parameter Specifications
Item Specification
Model C7012E1112/U
Product Type Dynamic self‑checking UV flame detector
Supply Voltage 120 V AC, 50/60 Hz
Power Consumption 7 W
Mounting Thread 1‑inch NPT
Housing Rating NEMA 4
View Window Pressure Rating 20 psi
Lead Wire Length 96 inch (2438 mm)
Operating Ambient Temperature -29 ℃ ~ +79 ℃
Compatible Amplifier R7247C, R7847C
Detectable Fuel Natural gas, LPG, fuel oil, pulverized coal
Certifications UL, CSA, FM, CE(EN298 with matched system)
Dimension 133 mm × 183 mm
Weight Approx.1.9 kg
Country of Origin USA

HONEYWELL C7012E1112/U Self Testing UV Flame Detector

Product features
  1. Dynamic mechanical self check function: The internal shutter periodically blocks the ultraviolet sensor, automatically verifying the hardware integrity of the probe, eliminating safety hazards caused by probe failure, and suitable for long-term continuous operation of the burner.
  2. The principle of ultraviolet spectroscopy detection is not affected by visible light and infrared thermal radiation interference in the furnace, and it is stable for flame recognition of gas, fuel oil, and coal powder.
  3. NEMA4 shell protection, dust-proof and splash proof, suitable for indoor and outdoor furnace installation scenarios; The quartz observation window can withstand a forward pressure of 20psi in the furnace.
  4. Support parallel use of dual probes, aimed at burners with large flame fluctuations and adjustment ratios, to reduce the probability of false flameout protection tripping, and can rotate and maintain a single probe online.
  5. The quartz window and ultraviolet sensing tube can be replaced separately on site, without the need to replace the probe as a whole, reducing spare parts costs.
    96 inch color coded pre installed cable for easy and convenient wiring; Flexible installation angle, can be installed horizontally, vertically, or diagonally.
  6. It is fully compatible with Honeywell 7700, 7800 series combustion management systems and R7247C/R7847C flame amplifiers.

HONEYWELL CC PCNT02(2) 2 HONEYWELL TC CCN014 2

Usage Scenarios

  1. Thermal power plant boilers: gas/oil boilers, coal powder boilers, burner flame monitoring, furnace shutdown safety protection.
  2. Petrochemical refining heating furnace: cracking furnace, reforming furnace, process heating furnace main fire and pilot flame detection.
  3. Metallurgical industry: Combustion safety monitoring for hot blast furnaces, heat treatment furnaces, and heating furnaces.
  4. Glass and ceramic kilns: Flame monitoring of gas and fuel burners in industrial kilns.
  5. The factory has its own boiler room and heating station: industrial gas boilers and oil fired boilers for combustion safety protection.
  6. Heating equipment for oil and gas process units: non explosion proof area burners, torches, and incinerator flame detection.

GE Mark VIe Series IS220PCNOH1B CANopen Communication I/O Module

T8461C | ICS TRIPLEX Trusted TMR Digital Output Module

GDB021BE01 HIEE300766R0001 Multi-channel Current Acquisition Module

ABB 3BHB030310R0001 5SHY4045L0006 3BHE039203R0101 GVC736CE10 IGCT series power module

PM866A 3BSE076359R1 ABB 800xA System Core Processor Unit (CPU)

PM511V16 3BSE011181R1 ABB Digital signal processing control board

PM891 | 3BSE053240R1 | ABB Central Processing Unit (CPU) Module

3BHE014070R0101 | PPC905AE101 | ABB PLC logic controller board

长欣外网名片 2

Share This Page
Related Products
Scroll to Top

Get A Free Quote Now!

Contact Form Demo (#3)